6 Mounting
Maschinenfabrik Reinhausen GmbH 2021
50
6796573/02 EN
MSENSE
®
VAM
6.2 Mounting the vibration sensor
When selecting the mounting position, ensure that there is the greatest pos-
sible clearance to the drive motor, drive shafts and pipelines to reduce the
disruptive effect on the vibro-acoustic recording to a minimum.
To mount the VAM sensor, proceed as follows:
1. Remove one bolt from the on-load tap-changer cover. Reuse the washer
that is present.
Figure 30: Removing bolt
2.
NOTICE!
Incorrect mounting can destroy the vibration sensor. Only apply
a tool with wrench size 17 to the lower hexagon of the adapter to attach
the sensor assembly. Place the washer over the open tapped hole and
screw in the sensor assembly (vibration sensor with adapter and kick
guard) with a torque of 34 Nm.