7.13.4 Operation of Screw Counter on SDC
The screw counter function of SDC controller can be used as a single
fastening quality monitoring devic
e.
■ P
arameter Setting for Single
parameter no.
Setting
Optional
P21
~28
Key in the min
imum angle
on P21 to 28 for fastening
OK of Preset no. 1 to 8.
Optional
P31
~38
Key in the ma
xi
mum turn on P31 to 38 for fastening
OK of Preset no. 1 to 8.
※
P130
Key in the numbers of screw to count.
ex) Key in "5" on P130 --> 5 screws
※
P80
Select one of Count Start signal type.
ex) select "2" One pulse type signal
Optional
P81
Time limit after the Cou
n
t Start
signal
ex) Key in "200" for 20
s
econds (unit 0.1 sec)
※
mark
settings are always necessary.
After setting the parameter above, the LCD display will show
on the work mode. The number 05 will be decrease one by one against the
screw fastening OK to "0". The number "0" will be reset to "05" on receipt of
Count Start of "One pulse type signal".