Number
Unit
Range
Initial
P100
0 or 1
0
Description
Selectable Free reverse rotation ( Enable/Disable )
0 : Disable 1 : Enable
Number
Unit
Range
Initial
P101
rpm
0 ~ 1,000
0
Description
Free reverse rotation speed setting
0 : No use
1 ~ 1,000 : Free reverse speed
15) Engaging Torque Detection Setting
Number
Unit
Range
Initial
P103
0 or 1
0
Description
Selectable Engaging torque detection ( Enable/Disable )
0 : Disable 1 : Enable
Number
Unit
Range
Initial
P104
rpm
0 ~ 1,000
0
Description
Engaging torque detection
speed setting
0 : No use
1 ~ 1,000 : Free reverse speed
Number
Unit
Range
Initial
P105
%
0 ~ 50
0
Description
Engaging torque value setting
Setting : 0 ~ 50%
( 0 = No use )
Number
Unit
Range
Initial
P106
turn
0 ~ 20.0
0
Description
Engaging torque detection angle limit ( 0 = No use )
Setting : 0 ~20 turn : Engaging torque can be detected before the angle
limit
Number
Unit
Range
Initial
P107
sec
0 ~ 10.0
0
Description
Engaging torque detection time limit ( 0 = No use )
Setting : 0~10sec : Engaging torque can be detected before time limit
1080 N 11th St - San Jose CA 95112 - mountztorque.com
33
Summary of Contents for SDC-24
Page 12: ...SD400 SD600 SD1000 SD1500 SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 12...
Page 69: ...2 Direct Wiring to 25P I O Interface Port 1080 N 11th St San Jose CA 95112 mountztorque com 69...
Page 90: ...9 Screw Count Monitoring Single 1080 N 11th St San Jose CA 95112 mountztorque com 90...