5) Max Angle Control
Number
Unit
Range
Initial
P31~38
0.1 turn (36
°
)
0 ~ 30.0
0
Description
"0" : No use "0.1~30.0" : Value of rotating angle (turn
)
Function #1 Angle control stop and verify OK
P79 Max angle control setting should be
" 0 " : Stop and verify OK
The driver stops at the set turn(angle) and provides fastening OK output
signal(pin #25). If the load reaches to the target torque, it stops
immediately even before the set turn(angle), and provides Torque-up and
Fastening OK output signal together
.
For example, it has 6.0Kgf.cm in P3, 500rpm in P13 and 5 turns in P33,
the driver will run with 500 rpm and stop at 5 turns (1800 degree). But if
the driver reaches to 6.0 Kgf.cm of the target torque before 5 turns, it will
stop immediately at any turn
.
Function #2 Limit of Fastening angle for NG detection
P79 Max angle control setting should be
" 1 " : Stop and verify NG ( Er332 )
If there is no torque up until the set angle(turn), it stops and provides NG
output signal with the error code E332.
This function is useful to protect the screw which is continuously running
around the screw hole without engaging.
The latest fastening angle(turn) can be monitored on the LCD display of
front panel
.