2) Fastening NG ( Angle lapse )
Error Code Display :
E r 3 3 1
If the driver reaches to the target torque before the Min. angle setting on
P21 ~ 28, it is NG. ( Angle lapse )
Even the torque reaches to the target, the screw is not fastened enough.
The LCD will display Er331 for set time and reset automatically.
3) Fastening NG ( No Torque up )
Error Code Display
:
E r 3 3 0
If fastening is cancelled over Min. angle on P21 ~ 28, it displays error code
330 when this NG verification is selected on P78
The operator accidentally releases the start lever just before the torque reaches to the
target. This is distinguished from the short idling run for screw pick-up from the screw
p
resenter. And it is the one of the serious qua
lity failure.