3) One Pulse Type Signal ( select "2" on P80 )
It starts counting number of screw on receipt of pulse signal. There is no Count Stop
signal. When the counting reaches to the target, it will provide the count complete OK
output signal.
But if the time after start is limited on P81, SDC will verify NG at the set time.
If the fastening is not complete till the set time, it will verify NG with the error code
E r 3 1 1
for 3 seconds and will display the remaining number.
It can be clear to the target by pressing RESET
but
t
on
E
x
a
m
p
l
e
#
1 )
C
o
u
nt start pulse signal with time limit
Example #2 ) Count start pulse signal
without
time limit
Without the fastening time limit after Start on P81, it can be a useful application with
a pallet conveyor system with stopper as shown below. The stopper does not go
down keeping the work piece in work area. If there is no Count complete
OK signal from the SDC.