Number
Unit
Range
Initial
P63~73
Descrip
t
ion
P63 Screw Seating Point ( Factory setting : 50 % )
Setting : 10 ~ 90 % of the target torque
P64 P1 setting in A2 process ( Factory setting : 40 % )
Setting : 10 ~ 60 % of the target torque
P65 P2 setting in A2 process ( Factory setting : 60 % )
Setting : 40 ~ 80 % of the target torque
P66 P3 setting in A2 process ( Factory setting : 80 % )
Setting : 60 ~ 95 % of the target torque
P67 Ramp up speed setting in A2 process with percentage
of the target speed ( Factory setting : 50 % )
Setting : 10 ~ 100 % of the target speed
P68 Torque rising time in ramp up process
( Factory setting : 100 mS )
Setting : 100 ~ 200 mS
P69 Start point of ramp up speed on P67
Selecting : P1, P2, or P3 ( Factory setting : P3 )
P70 Target torque holding time (Tm)
Setting : 10 ~ 100 mS ( Factory setting : 20 mS )
P72 Angle limit during torque holding(Tm) (E303)
( Factory setting : 0 )
Setting : 0 ~ 360° ( 0 = No use )
P73 Angle limit during Ramp-up process (E302)
( Factory setting : 0 )
Setting : 0 ~ 10
turns
( 0 = No use )
13) Motor Acceleration
Number
Unit
Range
Initial
P40
1ms
10 ~ 1000
200
Description
The motor increases the rotation speed up to the target in the set time.
It works for all preset #.
1080 N 11th St - San Jose CA 95112 - mountztorque.com
31
Summary of Contents for SDC-24
Page 12: ...SD400 SD600 SD1000 SD1500 SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 12...
Page 69: ...2 Direct Wiring to 25P I O Interface Port 1080 N 11th St San Jose CA 95112 mountztorque com 69...
Page 90: ...9 Screw Count Monitoring Single 1080 N 11th St San Jose CA 95112 mountztorque com 90...