Operation
8.2.4 3D setpoint assignment
If the controller receives external 3D setpoint settings (for
example, because a 3D-control with GPS or total station is
integrated), then it can be selected here whether these should
be utilised for the controlling or whether the default should still
be executed in the conventional way by manual entries made by
the operator using the keyboard.
A
=
Automatic
=
3D setpoint setting;
Hd =
Manual mode =
setpoint assignment is executed by
using keyboard entries;
Actuate the A/M-
button and the
Enter button
several times at
the same time ...
… until the display
between the
abbreviation for
the setpoint
assignment
“SP”
and the current
control type (here:
“A” for 3D setpoint
assignment)
By actuating the
UP or DOWN
button, the other
setpoint
assignment set
(here:
“Hd” for
setpoint
assignment for
input from the
keyboard) will be
set accordingly.
Working mode will
be switched back
to by actuating the
A/M button. If no
button is actuated,
then the controller
automatically
switches back to
this position after
5 seconds.
Summary of Contents for MOBA-Matic MMC-1000
Page 7: ...Table of contents 7 12 Declaration of conformity 161 ...
Page 79: ...Operation 79 Graphical representation of the user menu ...
Page 161: ...Declaration of conformity 161 12 Declaration of conformity ...
Page 162: ...162 Declaration of conformity ...
Page 163: ...Declaration of conformity 163 ...
Page 164: ...164 Declaration of conformity ...
Page 165: ...Declaration of conformity 165 ...
Page 166: ...166 Declaration of conformity ...
Page 167: ...Declaration of conformity 167 ...
Page 168: ...168 Declaration of conformity ...
Page 171: ...Notes ...