Operation
8.6.2 Controlling with the Dual-Sonic
Switch controller
with the
Auto/Manual button
to the
“Manual”
operating mode.
The
“AUTO”
function lamp is off.
Select Dual-Sonic
sensor as
described.
Align the tool to the
working position for
the zero adjustment
with the UP/DOWN
buttons on the
controller or the
operator unit on the
machine.
Align the sensor as
described in the
section for
assembling and
setting up over the
reference position.
Press the Enter
button.
The actual setpoint
value will be
acquired as the
setpoint value.
Press the Enter
button an hold for
approximately 2
seconds.
Actual value and
setpoint will be set
to
“0.0”.
Switch controller with
the Auto/manual key
into the
“Automatic”
operating mode. The
function lamp
“AUTO”
is on.
The controller stops
the tool on the set
value.
Use the UP/DOWN
buttons to amend
the setpoint value
in automatic mode
to be therefore able
to acquire
corrections.
5)
6)
4)
3)
2)
1)
Summary of Contents for MOBA-Matic MMC-1000
Page 7: ...Table of contents 7 12 Declaration of conformity 161 ...
Page 79: ...Operation 79 Graphical representation of the user menu ...
Page 161: ...Declaration of conformity 161 12 Declaration of conformity ...
Page 162: ...162 Declaration of conformity ...
Page 163: ...Declaration of conformity 163 ...
Page 164: ...164 Declaration of conformity ...
Page 165: ...Declaration of conformity 165 ...
Page 166: ...166 Declaration of conformity ...
Page 167: ...Declaration of conformity 167 ...
Page 168: ...168 Declaration of conformity ...
Page 171: ...Notes ...