88
Operation
The variable for the symmetry around the working point of the
control window is adjustable.
The setting will be executed, depending on the physical measuring
unit for the distance measurement, in 0.1 cm, 0.1 inch or 0.01 feet
increments.
The set value for the control window describes a range around the
working point; i.e. when a half a set value is once above and one
below the working point.
(Example: 6 cm control window = +/- 3 cm around the working
point)
Setting the control window
Simultaneously
actuate the A/M
button and the
Enter button
several times.
… until the display
between the symbol
for the control window
setting
and the last
set value (preset
“OFF” - is also
deactivated) switches
back and forth.
By pressing the
UP or DOWN
button, this
variable for the
control window
will be increased
or reduced (here:
setting to the
value
“8.0”[ ± 4.0 cm])
Working mode will
be switched back
to by actuating the
A/M button. If no
button is actuated,
then the controller
automatically
switches back to
this position after 5
seconds.
W orking point
Control
window
+1/2 adjusting value
-1/2 adjusting value
Summary of Contents for MOBA-Matic MMC-1000
Page 7: ...Table of contents 7 12 Declaration of conformity 161 ...
Page 79: ...Operation 79 Graphical representation of the user menu ...
Page 161: ...Declaration of conformity 161 12 Declaration of conformity ...
Page 162: ...162 Declaration of conformity ...
Page 163: ...Declaration of conformity 163 ...
Page 164: ...164 Declaration of conformity ...
Page 165: ...Declaration of conformity 165 ...
Page 166: ...166 Declaration of conformity ...
Page 167: ...Declaration of conformity 167 ...
Page 168: ...168 Declaration of conformity ...
Page 171: ...Notes ...