72
Operation
The zero adjustment is only effective for grade sensors and when
the digital controller is also located in the
“Manual” operating
mode.
If the tool and sensor(s) are set-up on the adjustment height, then
you should proceed with the zero adjustment as follows:
3) Select in the sensor selection for the digital controller for the
grade sensor to be adjusted.
4) Press the ENTER button and hold it down until the actual value
display
“Set” is displayed and after, another approx. 2 seconds,
the value springs to
“0.0”
The current measured value of the grade sensor (actual value)
will be acquired as the setpoint value and both variables will be
assigned the value 0.0. No control deviation exists.
If a sensor on the controller has been disconnected and t here is
no other sensor connected, then
“No / Sen” on the screen.
A sensor on the controller has been disconnected but a slope
sensor is, for example, still connected, then
“SLo / Sen” will
appear as a possible sensor on the display.
Adjustment
height
Adjustment
height
Summary of Contents for MOBA-Matic MMC-1000
Page 7: ...Table of contents 7 12 Declaration of conformity 161 ...
Page 79: ...Operation 79 Graphical representation of the user menu ...
Page 161: ...Declaration of conformity 161 12 Declaration of conformity ...
Page 162: ...162 Declaration of conformity ...
Page 163: ...Declaration of conformity 163 ...
Page 164: ...164 Declaration of conformity ...
Page 165: ...Declaration of conformity 165 ...
Page 166: ...166 Declaration of conformity ...
Page 167: ...Declaration of conformity 167 ...
Page 168: ...168 Declaration of conformity ...
Page 171: ...Notes ...