(6) Diode stack (P96 and P120 models)
Measure resistances between each pair of terminals on the diode stack with a tester, and use the results for troubleshoot-
ing.Refer to (5) " Intelligent power module (IPM) " for notes on measurement and tester selection.
Judgment value (reference)
Black ( + )
External view
+ (P)
- (N)
to (L1)
to (L2)
to (L3)
Red (-)
+ (P)
-
-
5 - 200
ohm
5 - 200
ohm
5 - 200
ohm
- (N)
-
-
to (L1)
5 - 200
ohm
-
-
-
Internal circuit diagram
to (L2)
5 - 200
ohm
-
-
-
to (L3)
5 - 200
ohm
-
-
-
L1 L2 L3
+
-