VI
Electrical Wiring Diagram ]
- 67 -
HWE10190
GB
VI
Electrical Wiring Diagram
[1] Electrical Wiring Diagram of the Outdoor Unit
1. Electrical wiring diagram of the outdoor unit
(1) PUHY-P250, 350, 400YJM-A
+-
+
+
+
+
2 1
+
+
+
+
+
3
3
2
2
Heat exchanger capacity control
Cooling/Heating switching
21S4b,c
*7
63HS1
SV9
SV5b,c
For opening/closing the bypass circuit under the O/S
21S4a
4-way valve
Explanation
Symbol
63H1
63LS
Pressure sensor
Pressure switch
High pressure protection for the outdoor unit
Discharge pressure
Low pressure
72C
Magnetic relay(inverter main circuit)
Current sensor(AC)
Crankcase heater(for heating the compressor)
CH1
1
CT12,22,3
HIC bypass,Controls refrigerant
flow in HIC circuit
Solenoid valve
Linear expansion valve
LEV1
LEV2
SV1a
DCL
D
C reactor
Pressure control,Refrigerant flow rate control
TB1
TB3
TB7
Te
rminal
block
Central control transmission cable
Indoor/Outdoor transmission cable
Power supply
TH2
TH3
TH4
TH5
TH6
TH7
THHS
Function setting connector
IPM temperature
OA
temperature
Subcooled liquid refrigerant temperature
ACC inlet pipe temperature
Discharge pipe temperature
Subcool bypass outlet temperature
Thermistor
Z24,25
Pipe temperature
Outdoor unit heat exchanger capacity control
For opening/closing the bypass circuit
21S4c
X08
1
5
X07
SV5c
3
CN507 red
6
P250
Appliance
*7.Dif
ference of appliance
Model name
*7 do not exist
*7 exist
P350/P400
3
CN3 green
1
N
N
L
N
TB24
*1.Single-dotted lines indicate wiring not supplied with the unit. *2.Dot-dash lines indicate the control box boundaries. *3.Refer to the Data book for connecting input/output signal connectors. *4.Daisy-chain terminals (TB3) on the outdoor units in the same refrigerant system together
.
*5.Faston terminals have a locking function. Make sure the terminals are securely locked in place after insertion. Press the tab on the terminals to remove them. *6.Control box houses high-voltage parts. Before inspecting the inside of the control box,turn of
f the power
,keep
the unit of
f for at least 10 minutes,
and confirm that the voltage between FT
-P
and FT
-N on INV Board has dropped
to DC20V or less.
L3
L1
L2
Power Source
3N~
50/60Hz
380/400/415V
21S4b
CN501
X01
1
3
X09
3
6
CN508 black
Unit address setting
CN504 green
CT12
C31
C33
CN5 red
D1
R4
Z5
1
SV9
R631
white
TH2
t°
C8
red CNIT
yellow CNS2
t°
1
1
LED1 Display setting
CN51
12V
Function setting
SW1
10
1
CN212
CNTYP4 green
F4 AC250V 6.3A
T
R5
F3
F1
Z4
R2
F2
*3
3
2
Compressor ON/OFF output Error detection output
CN201
Z25
1
4
1
1
1
TH3
Z3
3
Z2
U
ON
OFF
SW2
10
1
SWU2
LED1
C4
C35
C37
R31
R33
R30
ON
SW3
10
Control Board
TH7
CN40
63HS1
CN41
TH6
t
°t
TH4
3
2
2
2
1
SW5
LED3:Lit when powered
1
3
4
R32
2
Z1
1
DSA
C10
R34
R35
LEV1
LEV2
C36
3
C34
SC-V
CT22
SC-U
V
1
CN4 blue
red
1
M
1
1
t
LED3:CPU in
operation
black
4
1
CNTYP2 black
3
6
yellow CN3K
*3
3
M
C3
TB21
C1
R3
3
CN1A
5
U
CN2
blue CN3N
5
6
C7
U
4
4
R1
CN21 blue
TB1
1
CN1B
3
TB7 Power selecting connector
CN102
CNVDC
3
2
1
IPM
2
1
U
4
TP1
W
L3
DCL
V
black
72C
white
red
3
2
1
ON
OFF
1
M-NET
power
supply circuit
1
2
3
C6
M-NET
Board
1
2
1
Power failure detection circuit
1
CNAC2 black
CN502
5
Indoor/Outdoor transmission cable
INV Board
red
3
CNT01
TB23
L2
L1
U
4
1
ON
1
2
1's digit
THHS
1
CNIT red
S
2
1
1
CN990
1
3
W
TB3
10's digit
OFF
LED2:CPU in operation
5
2
CNS2 yellow
TB7
1
CNDC pink
M1
2
2
red
6
MS 3~
1
1
t
C100
*5
3
3
U
1
4
LED1:Power supply to
Indoor/Outdoor transmission line
ZNR01
M2
32
M1
black
Central control transmission cable
*6
SC-L1
1
4
C2
C9
ON
C5
OFF
FT
-N
R5
M 3~
Motor
(Compressor)
°
CN5V yellow
5
2
3
3
3
red CN3S
1
1
CN04 red
1
CN2
2
3
CN4
X05
2
2
Fan motor (Heat exchanger)
SC-P2
P
1
CN21
1
CN202 red
TH5
°
N
CN1
M2
2
TP2
LED1:Normal operation(Lit)
/ Error(Blink)
2
CN503 blue
5
X04
4
*4
SC-W
U
C32
SC-L3
CH1
1
CN506
1
2
CN72 red
3
P
63H1
CN801 yellow
1
2
CN332 blue
F1,F2,F3 AC250V 6.3A
T
2
1
OFF
SW4
10
1
CNT02
11
CN3D
4
3
2
1
21
CPU power supply circuit
CNAC red
2
1
F01 AC250V 3.15A
T
1
t
ON
OFF
10
SWU1
white
CN213 red
SC-L2
3
Z24
7
4
°
3
2
1
1
2
2
7
1
2
CN5
1
CN4 red
CNINV
3
4
R630
1
1
C630
3
CN22 red
C631
5
F01 DC700V 4A
T
1
CNTYP5 green
4
LED2:Error
21S4a
1
LED1:Normal
operation
2
3 2
U
X02
X03
CN18V blue
5
1
7
CN4
3
CN6
2
°
IPM
4
SC-P1
FT
-P
black
C30
red
DB1
CT3
72C
C1
CN2
CNTYP black
R1
black
TB22
6
3
RSH1
CN102
3
R6
C1
1
1
1
1
FAN Board
63LS
ZNR1
U
3
Noise Filter
SV5b
red
CNL
VA
CNL
VB
red
1
2
3
4
5
6
white
black
SV1a
6
4 3 2 1
2
1
L1
L2
L3
CN215 black
<Symbol explanation>
0000002115.book 67 ページ 2011年6月4日 土曜日 午前10時48分
Summary of Contents for PUHY-P250YJM-A
Page 1: ......
Page 11: ... 2 HWE10190 GB ...
Page 25: ... 16 HWE10190 GB ...
Page 45: ... II Restrictions 36 HWE10190 GB ...
Page 47: ... 38 HWE10190 GB ...
Page 57: ... 48 HWE10190 GB ...
Page 69: ... IV Indoor Unit Components 60 HWE10190 GB ...
Page 71: ... 62 HWE10190 GB ...
Page 73: ... V Remote Controller 64 HWE10190 GB ...
Page 75: ... 66 HWE10190 GB ...
Page 83: ... 74 HWE10190 GB ...
Page 91: ... VII Refrigerant Circuit 82 HWE10190 GB ...
Page 93: ... 84 HWE10190 GB ...
Page 115: ... VIII Control 106 HWE10190 GB ...
Page 117: ... 108 HWE10190 GB ...
Page 137: ... 128 HWE10190 GB ...
Page 225: ... X Troubleshooting 216 HWE10190 GB ...
Page 227: ... 218 HWE10190 GB ...
Page 272: ......