Specifications
Indoor unit
model
PFAV-P900VM-E-F
Outdoor unit
model
PUHY-P750YSJM-A
PUHY-P400YJM-A
PUHY-P350YJM-A
Operating
conditions
Ambient
tempera-
ture
Indoor
DB/WB
7°C/- [45°F/-]
Outdoor
7°C/3°C [45°F/37°F]
Piping
Main pipe
m[ft]
7.5 [24-1/4]
Refrigerant charge
kg
[lbs-oz]
33.2 [73-3]
Outdoor
unit
Electric current
A
41.7
Voltage
V
400
Compressor frequency
Hz
101
101
LEV open-
ing
Indoor unit
Pulse
708
SC(LEV1)
0
LEV2
2100
2100
Pressure
High pressure (after O/S)/Low
pressure (before accumulator)
MPa
[psi]
2.73/0.54 [384/84]
2.73/0.54 [384/84]
Temp. of
each sec-
tion
Outdoor
unit
Discharge (TH4)
°C [°F]
75 [167]
75 [167]
Heat exchanger out-
let (TH3)
1 [35]
1 [35]
Accumulator inlet
-1 [32]
-1 [32]
Accumulator outlet
-1 [32]
-1 [32]
Compressor suction
-1 [32]
-1 [32]
Compressor shell
bottom
21 [73]
21 [73]
Indoor
unit
LEV inlet
32 [86]
Heat exchanger out-
let
70 [158]
0000002115.book 126 ページ 2011年6月4日 土曜日 午前10時48分
Summary of Contents for PUHY-P250YJM-A
Page 1: ......
Page 11: ... 2 HWE10190 GB ...
Page 25: ... 16 HWE10190 GB ...
Page 45: ... II Restrictions 36 HWE10190 GB ...
Page 47: ... 38 HWE10190 GB ...
Page 57: ... 48 HWE10190 GB ...
Page 69: ... IV Indoor Unit Components 60 HWE10190 GB ...
Page 71: ... 62 HWE10190 GB ...
Page 73: ... V Remote Controller 64 HWE10190 GB ...
Page 75: ... 66 HWE10190 GB ...
Page 83: ... 74 HWE10190 GB ...
Page 91: ... VII Refrigerant Circuit 82 HWE10190 GB ...
Page 93: ... 84 HWE10190 GB ...
Page 115: ... VIII Control 106 HWE10190 GB ...
Page 117: ... 108 HWE10190 GB ...
Page 137: ... 128 HWE10190 GB ...
Page 225: ... X Troubleshooting 216 HWE10190 GB ...
Page 227: ... 218 HWE10190 GB ...
Page 272: ......