[
IV
Indoor Unit Components ]
- 51 -
HWE10190
GB
3. PFAV-P750VM-E
Minimum necessary dimension.
Indoor unit
Required space for service and air flow
Secure the proper space for installation work
such as piping and wiring separately
.
Please secure the size of *sign when you serve
the air filter from the right side of the main body
.
Notes 1.Please secure the size in the service space of the air filter(*sign)
for a left side or a right side of the unit.
2.Be sure to wire the transmission line and power line separately
.
3.When the room in which the unit is installed is airtight,
the pressure in the room may become negative.
This may result in problems such as the door to becoming dif
ficult
to open etc.
T
o
avoid these kinds of problems please ensure that a small amount of
air is able to ventilate the room via some kind of small hole or vent.
4.Connect by using the connecting pipes that are supplied.
(Size on inside)
(Size on inside)
2
5
6
3
4
(Size on inside)
8
7
2
1
5
6
Air filter
12
5
6
1
(Size on inside)
476
56
439
606
30
12
476
11
0X4=440
18
20-ø4.3Holes
606
1
1
0X4=440
83
42
750
500
1000
400
580
100
875
810
740
450
220
150
11
2
493
994
741
70
35
10
1212
106
200X5=1000
(599)
106
300
195
715
25
30
*750
(106)
1460
200X7=1400
(146)
*750
30
200
10
(50)
1722
50
1045
976
300
1830
30
615
75
1822
1774
1750
140
100
490
220
150
191
261
Supply air duct flange
28-ø4.3Holes
note:1
Air filter service space
Remote controller
Supply air duct flange
Drain hole<Lower side>······Rc 1
Earth terminal(installed in the control box)······M5
Wiring hole(The outdoor unit connection,T
ransmission line)······ø38
For mounting anchor bolt 4-ø15 Holes
Wiring hole······ø62
Drain hole<Upper part>······Rc 1 1/4
Refrigerant pipe<Liquid>···ø19.05 brazed
Refrigerant pipe<Gas>···ø34.93 brazed
Designation
NO.
1
2
3
4
5
6
7
8
Unit:mm
0000002115.book 51 ページ 2011年6月4日 土曜日 午前10時48分
Summary of Contents for PUHY-P250YJM-A
Page 1: ......
Page 11: ... 2 HWE10190 GB ...
Page 25: ... 16 HWE10190 GB ...
Page 45: ... II Restrictions 36 HWE10190 GB ...
Page 47: ... 38 HWE10190 GB ...
Page 57: ... 48 HWE10190 GB ...
Page 69: ... IV Indoor Unit Components 60 HWE10190 GB ...
Page 71: ... 62 HWE10190 GB ...
Page 73: ... V Remote Controller 64 HWE10190 GB ...
Page 75: ... 66 HWE10190 GB ...
Page 83: ... 74 HWE10190 GB ...
Page 91: ... VII Refrigerant Circuit 82 HWE10190 GB ...
Page 93: ... 84 HWE10190 GB ...
Page 115: ... VIII Control 106 HWE10190 GB ...
Page 117: ... 108 HWE10190 GB ...
Page 137: ... 128 HWE10190 GB ...
Page 225: ... X Troubleshooting 216 HWE10190 GB ...
Page 227: ... 218 HWE10190 GB ...
Page 272: ......