PART No. 9374343430

ARXA024GLEH

ARXA030GLEH

ARXA036GLEH

ARXA045GLEH

English

OPERATING MANUAL

INDOOR UNIT (Duct type)

Keep this manual for future reference.

Deutsch

BEDIENUNGSANLEITUNG

INNENGERÄT (Kanaltyp)

Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf.

Français

Español

MODE D’EMPLOI

MANUAL DE FUNCIONAMIENTO

UNITÉ INTÉRIEURE (type conduit)

UNIDAD INTERIOR (Tipo conducto)

Conservez ce manuel pour pour toute référence ultérieure.

Conserve este manual para posibles consultas futuras.

Italiano

MANUALE DI ISTRUZIONI

UNITÀ INTERNA (tipo a condotto)

Conservare questo manuale per consultazione futura.

Ελληνικ

ά

Português

ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ

ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ (Τύπος αγωγού)

Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά.

MANUAL DE FUNCIONAMENTO

UNIDADE INTERIOR (Tipo de tubagem)

Guarde este manual para consulta futura.

Ру

сский

Türkçe

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

ВНУТРЕННИЙ МОДУЛЬ (Короб)

Сохраните данное руководство для последующего использования.

KULLANIM KILAVUZU

İÇ ÜNİTE (Kanal tipi)

Bu kılavuzu ileride başvurmak üzere saklayın.

[Original instructions]

MADE IN P.R.C.

Refer to the rating label for the serial number, 

manufactured year and month.

9374343430_OM.indb   1

07/02/2019   14:59:46

Summary of Contents for AirStage ARXA024GLEH

Page 1: ...iano MANUALE DI ISTRUZIONI UNITÀ INTERNA tipo a condotto Conservare questo manuale per consultazione futura Ελληνικά Português ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπος αγωγού Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR Tipo de tubagem Guarde este manual para consulta futura Русский Türkçe РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ Короб Со...

Page 2: ...n the unit directly or wash the unit with them Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pressure to radiator fins Do not use inflammable gases near the air conditi...

Page 3: ...result ing in reduced operating performance In order to prevent this kind of reduced performance this unit is equipped with a Microcomputer con trolled automatic defrosting function If frost forms the air conditioner will temporarily stop and the defrosting circuit will operate briefly for about 4 to 15 minutes During Automatic Defrosting operation the OPERATION indicator lamp green will flash lim...

Page 4: ...ling sound may be heard occasionally This sound is produced by the Automatic Defrosting operation See page 2 Smells Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Fog comes out of the indoor unit During Cooling operation a thin mist may be seen emitted from the indoor unit This results from...

Page 5: ...4 240 CURRENT A 0 60 0 69 1 18 1 43 SOUND PRESSURE LEVEL HIGH dB A 31 34 37 41 MED HIGH dB A 29 33 36 40 MED dB A 27 32 35 38 MED LOW dB A 26 31 35 38 LOW dB A 24 30 34 37 QUIET dB A 23 29 33 36 DIMENSIONS WEIGHT HEIGHT mm 270 WIDTH mm 1 135 DEPTH mm 700 WEIGHT kg 36 40 Acoustic Noise Information The maximum sound pressure level is less than 70 dB A for both indoor unit and outdoor unit According ...

Page 6: ...9374343430_OM indb 6 07 02 2019 14 59 54 ...