XI
LED Monitor Display on the Outdoor Unit Board ]
- 245 -
HWE10190
Setting data
No
.
SW1
Ite
m
Disp
la
y
Un
it
(A
, B
)
*1
Re
m
ark
s
12
34
567
89
0
L
D1
LD
2
LD3
LD4
L
D5
L
D
6
L
D7
LD
8
O
C
O
S
51
2
00
00
000
00
1
S
e
lf-
ad
dr
es
s
A
lter
nat
e
d
is
pl
ay
of
s
el
f a
dd
re
ss
a
nd
u
ni
t mo
de
l
A
A
51
3
10
00
000
00
1
IC/
FU ad
dr
es
s
C
ou
nt
-u
p di
sp
la
y o
f nu
mbe
r o
f co
nn
ec
te
d un
its
B
51
4
01
00
000
00
1
RC a
ddr
es
s
C
ou
nt
-u
p di
sp
la
y o
f nu
mbe
r o
f co
nn
ec
te
d un
its
B
51
5
11
00
000
00
1
51
6
00
10
000
00
1
O
S
a
dd
re
ss
C
ou
nt
-u
p di
sp
la
y o
f nu
mbe
r o
f co
nn
ec
te
d un
its
B
51
7
10
10
000
00
1
V
e
rs
ion/
Ca
pa
ci
ty
S/
W ver
si
o
n -> Re
fr
iger
an
t t
yp
e -
>
Mo
de
l an
d ca
pa
ci
ty
-> Co
mmuni
ca
tio
n ad
dr
es
s
A
A
51
8
01
10
000
00
1
O
C a
ddr
es
s
O
C ad
dr
es
s di
sp
la
y
B
51
9
11
10
000
00
1
52
0
00
01
000
00
1
52
1
10
01
000
00
1
52
2
01
01
000
00
1
*1
A:
The
c
on
di
tio
n of
ei
ther
OC or
OS is
di
sp
la
ye
d in
di
vi
d
ual
ly
. B:
The
c
on
di
tio
n of
th
e en
tir
e r
ef
rig
e
ra
nt
sy
st
em i
s di
sp
la
yed.
0000
0021
15.b
ook
245
ペー
ジ
20
11
年6
月4
日
土曜日
午
前1
0時
48
分
Summary of Contents for PUHY-P250YJM-A
Page 1: ......
Page 11: ... 2 HWE10190 GB ...
Page 25: ... 16 HWE10190 GB ...
Page 45: ... II Restrictions 36 HWE10190 GB ...
Page 47: ... 38 HWE10190 GB ...
Page 57: ... 48 HWE10190 GB ...
Page 69: ... IV Indoor Unit Components 60 HWE10190 GB ...
Page 71: ... 62 HWE10190 GB ...
Page 73: ... V Remote Controller 64 HWE10190 GB ...
Page 75: ... 66 HWE10190 GB ...
Page 83: ... 74 HWE10190 GB ...
Page 91: ... VII Refrigerant Circuit 82 HWE10190 GB ...
Page 93: ... 84 HWE10190 GB ...
Page 115: ... VIII Control 106 HWE10190 GB ...
Page 117: ... 108 HWE10190 GB ...
Page 137: ... 128 HWE10190 GB ...
Page 225: ... X Troubleshooting 216 HWE10190 GB ...
Page 227: ... 218 HWE10190 GB ...
Page 272: ......