30
3.2
Performance Specifications
The following describes the performance specifications of the Ethernet adapter module.
Item
Specification
Number of
device points
X
8192 points, 1KB (X0 to X1FFF are assigned to RX0 to RX1FFF.)
Y
8192 points, 1KB (Y0 to Y1FFF are assigned to RY0 to RY1FFF.)
W
8192 points, 16KB (1024 points of W0 to W3FF are assigned to RWw0 to RWw3FF. 1024 points of
W1000 to W13FF are assigned to RWr0 to RWr3FF.)
SB
8192 points, 1KB
SW
8192 points, 16KB
SM
2048 points, 256 bytes
SD
2048 points, 4KB
Number of writes to the
parameter memory
Up to 100000 times
Clock function (for display of
data such as the date and time at
which an error occurred)
Year, month, date, hour, minute, and second (with automatic leap year detection)
When connected to a network, the clock is periodically synchronized with the clock in the CPU module
on the master station via the network. (Initial value: 2000/1/1 00:00:00)
If the Ethernet adapter module is powered off and then on, the clock will restart at the time the power
was turned off. (The clock does not run while the power is off.)
Therefore, the date and time of an error that occurred during initial processing may be different from the
actual date and time.)
Internal current consumption
(24VDC)
0.6A
External
dimensions
H
90mm
W
135mm
D
109mm
Weight
0.7kg