206
Appendix 1.1
Module operation area
The operating status of the Ethernet adapter module is stored.
(1) Module LED information (buffer memory address: 0 (0
H
))
Information on the LED status of the CC-Link IE Field Network part is stored in the following bit pattern.
0: Off
1: On
1) D LINK LED
2) RD LED
*1
3) L ERR. LED
4) RUN LED
5) MODE LED
6) SD LED
*1
7) ERR. LED
*1
These LEDs can be used only when the Ethernet adapter module is in the online mode. The LED display is not changed
while the Ethernet adapter module is in the offline mode.
(2) Station No. LED information (buffer memory address: 1 (1
H
))
The status information on the LEDs indicating the station number on the CC-Link IE Field Network part is stored
in the following bit pattern.
0: Off
1: On
1) 1 for
1
2) 2 for
1
3) 4 for
1
4) 8 for
1
5) 1 for
10
6) 2 for
10
7) 4 for
10
8) 8 for
10
9) 1 for
100
0(0
H
)
b0
b1
b2
b3
b4
b5
b6
b7
b8
b9
b10
b11
b12
b13
b14
b15
1)
2)
3)
4)
6)
5)
7)
0
0
0
0
0
0
0
0
0
1(1
H
)
b0
b1
b2
b3
b4
b5
b6
b7
b8
b9
b10
b11
b12
b13
b14
b15
1)
2)
3)
4)
5)
6)
7)
8)
9)
0
0
0
0
0
0
0