WWW.NNC.IR
10 - 14
10. TROUBLESHOOTING
Display
Name
Definition
Cause
Action
1. PLC ladder program wrong.
Contact the program.
AL.E5 ABS time-out
warning
2. Reverse rotation start (ST2) Limiting
torque (TLC) improper wiring
Connect properly.
AL.E6 Servo emergency
stop warning
EMG is off.
External emergency stop was made valid.
(EMG was turned off.)
Ensure safety and deactivate
emergency stop.
AL.E9 Main circuit off
warning
Servo-on (SON) was
switched on with main
circuit power off.
Switch on main circuit power.
1. PLC ladder program wrong.
1. Correct the program.
AL.EA ABS
servo-on warning
Servo-on (SON) turned on
more than 1s after servo
amplifier had entered
absolute position data
transfer mode.
2. Servo-on (SON) improper wiring.
2. Connect properly.
Summary of Contents for MR-J2S-*A
Page 13: ...WWW NNC IR A 12 MEMO ...
Page 117: ...WWW NNC IR 3 70 3 SIGNALS AND WIRING MEMO ...
Page 185: ...WWW NNC IR 7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Page 195: ...WWW NNC IR 8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 197: ...WWW NNC IR 9 2 9 INSPECTION MEMO ...
Page 221: ...WWW NNC IR 11 10 11 OUTLINE DIMENSION DRAWINGS MEMO ...
Page 293: ...WWW NNC IR 13 64 13 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Page 321: ...WWW NNC IR 14 28 14 COMMUNICATION FUNCTIONS MEMO ...
Page 389: ...WWW NNC IR 15 68 15 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...