Examples of standard wiring diagrams
Connection
MELSERVO J2-Super
3 - 25
Servo amplifier 400V
S001255C
Fig. 3-29:
Standard wiring diagram for amplifier 400V
L3
L3
L2
L2
L1
L11
L21
C
D
P
U
V
W
T E 1
C N 2
C N 3
1 9
1 2
1 1
2
1
2 0
1 3
5
1 0
4
1
1 4
1 1
5
1 6
7
1 7
8
1 8
PLATE
3
1 1
2 0
1 2
1 8
2
7
1 7
6
1 6
9
1
PLATE
P 5
T x D
R D
G N D
S D
G N D
L G
R x D
L G
E M 1
M B R
C O M
V D D
M O 1
L G
M O 2
L G
L A
L A R
L B
L B R
L Z
L Z R
S D
C S 1
C S 1
C S 1
S G
L G
P 5
L G
P 5
L G
M R
M R R
M D
M D R
B AT
L G
S D
M R -B A T
C O N 1
TE
2
CN
1
A
M C
M
L1
I>
I>
I>
24 V D C
E M G
B 2
B 1
A
A
R A
A
B
C
D
G
H
CN
1
B
CN
1
A
CN
1
B
CN
1
A
CN
1B
S
R
C
D
A
B
F
G
N
M
E
N
CO
DE
R
P
N
/
/
/
Power
supply
Optional brake
resistor
(connection of a
brake unit to servo
amplifiers with
350B4 or more is
shown on the left)
Encoder A-phase
pulse
Encoder B-phase
pulse
Encoder Z-phase
pulse
PC
Make up a sequence which
switches off the MC at alarm
occurence or emergency stop.
MR-J2HBUS M-A cable
is connected to CN1A
Controller
A171SH
A172SH
A173UH
Monitor output 1
10k
Ω
Monitor output 2
10k
Ω
15m max.
10m max.
2m max.
MR-J2S- B4
MR-J2S- B4
Terminator
MR-A-TM
MR-J2HBUS M cable
is connected between
2 amplifiers
Servo motors
HC-SFS
MR-J2S- B4
Summary of Contents for MELSERVO MRJ2S-B
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...VIII ...
Page 18: ...Contents XII ...
Page 48: ...Introduction System configuration 1 30 ...
Page 58: ...Installation General environmental conditions 2 10 ...
Page 86: ...Connection Station number setting 3 28 ...
Page 122: ...Operation Gain 4 36 ...
Page 134: ...Absolute position detection system General description 6 6 ...
Page 146: ...Accessories Special accessories 7 12 ...
Page 148: ...Maintenance and Inspection Life 8 2 ...
Page 174: ...Specifications Standard specifications 10 16 ...
Page 176: ...EMC Directives Requirements 11 2 ...
Page 198: ...Index iv ...
Page 199: ......