Alarms and Warnings
Troubleshooting
MELSERVO J2-Super
9 - 9
Display
Error
Definition
Cause
Action
8E
Serial
communication
error
Serial
communication error
occurred between
servo amplifier and
personal computer.
1. Communication cable fault
(Open cable or short circuit).
Repair or change
the cable
2. Personal computer faulty
Change the
personal computer
88
Watchdog
CPU, parts faulty
Fault of parts in servo amplifier
Checking method: Alarm (88) occurs if
power is switched on after CN1A,
CN1B and CN3 connectors are
disconnected.
Change the servo
amplifier
Tab. 9-2:
Failure corrective action (6)