Operation
Gain
4 - 34
4.6.6
Differences in auto tuning between MR-J2 and MR-J2S
Response level
In comparison to the servo amplifiers of the MR-J2-Series the area for setting response levels
has been extended for servo amplifiers of the MR-J2-Super-Series.
S000988C
Fig. 4-10:
Response level setting (parameter No. 9)
MR-J2
MR-J2-Super
Response level
Machine resonance
Response level
Machine resonance
—
—
1
15Hz
1
20Hz
2
20Hz
—
—
3
25Hz
4
30Hz
5
35Hz
2
40Hz
6
45Hz
—
—
7
55Hz
3
60Hz
8
70Hz
4
80Hz
9
85Hz
5
100Hz
A
105Hz
—
—
B
130Hz
C
160Hz
D
200Hz
E
240Hz
F
300Hz
Tab. 4-23:
Response level comparison
NOTE
Because of a slight difference in gain adjustment pattern, response may not be the same if
the resonance frequency is set to the same value.
0