Connection of servo amplifier
Connection
MELSERVO J2-Super
3 - 7
3.1.4 Interfaces
The connection of external periphery to the interface described in section 3.1.3 is covered in the
following.
Digital input interface DI-1
Give a signal with a relay or open collector transistor.
S001007C
Fig. 3-2:
External device connection
V D D
T r
C O M
4.7 k
Ω
E M 1
S G
24V D C
app ro x. 5 m A
U
C ES
≤
≤
1V
I
100 µA
C EO
Servo amplifier