Troubleshooting
Alarms and Warnings
9 - 2
Deactivate the alarm about 30 minutes of cooling time for servo amplifier, servo motor and
brake unit after removing the cause of occurrence.
Display
Meaning
Alarm deactivation
Power
OFF ON
RESET
command
CPU reset
Alar
me
92
Open battery cable warning
Removing the cause of occurrence deactivates the alarm
automatically.
96
Home position setting warning
9F
Battery warning
E0
Excessive regenerative warning
E1
Overload warning
E3
Absolute position counter warning
E4
Parameter warning
E6
Servo forced stop warning
E7
Controller emergency stop
warning
E9
Main circuit off warning
EE
SSCNET error warning
Tab. 9-1:
Alarm and warning overview (2)