VI
Configuration
Environment
Operate the servo amplifier at or above the contamination level 2 set forth in IEC60664-1. For
this purpose, install the servo amplifier in a control box which is protected against water, oil,
carbon, dust, dirt, etc. (IP54).
Grounding
To prevent an electric shock, always connect the protective earth terminals of the servo amplifier
to the protective earth of the control box. Do not connect two or more ground cables to the same
protective earth terminal.
S00500C
S00501C
NFB
MC
M
Reinforced
insulating
transformer
No-fuse
breaker
Magnetic contactor
Power
supply
Control power
supply
Servo
amplifier
Servo
motor
Earth terminal
Earth terminal