Introduction
Removal and reinstallation of the front cover
1 - 10
1.4
Removal and reinstallation of the front cover
For models MR-J2S-200B or larger the front cover must be removed before the battery holder
and terminal strips for connecting the power supply of the motor TE1) and control voltage (TE2)
are accessible.
Removal the front cover for MR-J2S-200B and MR-J2S-350B
Hold down the removing knob.
Pull the front cover toward you.
Reinstallation the front cover for MR-J2S-200B and MR-J2S-350B
Insert the front cover hooks into the front cover sockets of the servo amplifier.
Press the front cover against the servo amplifier until the removing knob clicks.
m
DANGER:
Prior to removing the front cover the power supply must be switched off and at least
10 minutes must then elapse. This time interval is required for the condensers to
discharge to a harmless voltage level after turning off the mains power supply.
Abb. 1-11:
Removal the front cover
S000513C
Abb. 1-12:
Reinstallation the front cover
S000514C
Summary of Contents for MELSERVO MRJ2S-B
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...VIII ...
Page 18: ...Contents XII ...
Page 48: ...Introduction System configuration 1 30 ...
Page 58: ...Installation General environmental conditions 2 10 ...
Page 86: ...Connection Station number setting 3 28 ...
Page 122: ...Operation Gain 4 36 ...
Page 134: ...Absolute position detection system General description 6 6 ...
Page 146: ...Accessories Special accessories 7 12 ...
Page 148: ...Maintenance and Inspection Life 8 2 ...
Page 174: ...Specifications Standard specifications 10 16 ...
Page 176: ...EMC Directives Requirements 11 2 ...
Page 198: ...Index iv ...
Page 199: ......