Alarms and Warnings
Troubleshooting
MELSERVO J2-Super
9 - 1
9
Troubleshooting
9.1 Alarms
and
Warnings
9.1.1
Alarms and warning list
When a fault occurs during operation, the corresponding alarm or warning is displayed. If any
alarm or warning has occurred, refer to section 9.1.2 or section 9.1.3 and take the appropriate
action.
Display
Meaning
Alarm deactivation
Power
OFF
ON
RESET
command
CPU reset
Alar
ms
10
Undervoltage
✓
✓
✓
12
Memory error 1
✓
—
—
13
Clock error
✓
—
—
15
Memory error 2
✓
—
—
16
Encoder error 1
✓
—
—
17
Board error
✓
—
—
19
Memory error 2
✓
—
—
1A
Motor combination error
✓
—
—
20
Encoder error 2
✓
—
—
24
Main ciruit error
✓
✓
✓
25
Absolute position erase
✓
—
—
30
Regenerative error
✓
✓
✓
31
Overspeed
✓
✓
✓
32
Overcurrent
✓
✓
✓
33
Overvoltage
✓
✓
✓
34
CRC error
✓
✓
✓
35
Command frequency error
✓
✓
✓
36
Transfer error
✓
✓
✓
37
Parameter error
✓
—
✓
45
Main circuit device overheat
✓
✓
✓
46
Servo motor overheat
✓
✓
✓
50
Overload 1
✓
✓
✓
51
Overload 2
✓
✓
✓
52
Error excessive
✓
✓
✓
8E
Serial communication error
✓
✓
✓
88
Watchdog
✓
—
—
Tab. 9-1:
Alarm and warning overview (1)
Summary of Contents for MELSERVO MRJ2S-B
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...VIII ...
Page 18: ...Contents XII ...
Page 48: ...Introduction System configuration 1 30 ...
Page 58: ...Installation General environmental conditions 2 10 ...
Page 86: ...Connection Station number setting 3 28 ...
Page 122: ...Operation Gain 4 36 ...
Page 134: ...Absolute position detection system General description 6 6 ...
Page 146: ...Accessories Special accessories 7 12 ...
Page 148: ...Maintenance and Inspection Life 8 2 ...
Page 174: ...Specifications Standard specifications 10 16 ...
Page 176: ...EMC Directives Requirements 11 2 ...
Page 198: ...Index iv ...
Page 199: ......