General environmental conditions
Installation
MELSERVO J2-Super
2 - 7
Protection from oil and water
When the gear box is mounted horizontally, the oil level in the gear box should always be lower
than the oil seal lip on the servo motor shaft. If it is higher than the oil seal lip, oil will enter the
servo motor, leading to a fault. Make sure there is a ventilation hole in the gear box to prevent
any pressure build up in the gear box.
The following table presents an overview of the minimum clearances between the oil level and
the servo motor shaft centre:
Servo motor
Height above oil level [mm]
HC-SFS
52 to 152
20
524 to 1524
202 to 702
25
2024 to 7024
HC-RFS
103 to 503
20
Tab. 2-5:
Minimum clearances between the oil level and the servo motor shaft centre
S000525C
Fig. 2-8:
Arrangement
b
CAUTION:
The servo motors in the HC-MFS- and KC-KFS-Series do not have any oil seal on the
shaft. Here the sealing must occur on the gear side.
Servo motor
V ring
Height above oil level
Gear
Lip
h
Summary of Contents for MELSERVO MRJ2S-B
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...VIII ...
Page 18: ...Contents XII ...
Page 48: ...Introduction System configuration 1 30 ...
Page 58: ...Installation General environmental conditions 2 10 ...
Page 86: ...Connection Station number setting 3 28 ...
Page 122: ...Operation Gain 4 36 ...
Page 134: ...Absolute position detection system General description 6 6 ...
Page 146: ...Accessories Special accessories 7 12 ...
Page 148: ...Maintenance and Inspection Life 8 2 ...
Page 174: ...Specifications Standard specifications 10 16 ...
Page 176: ...EMC Directives Requirements 11 2 ...
Page 198: ...Index iv ...
Page 199: ......