Specifications
Standard specifications
10 - 12
The figure stated for the number of braking cycles per minute when addressing the braking
unit is the permitted figure of braking cycles per minute when the servo motor is braked
without any load from the rated speed to a standstill. If the motor is under load, then the
figure in the table must be multiplied by 1/(m + 1) (m = load moment of inertia / motor
moment of inertia).
If the recorded torque is within the range of the rated torque, then the number of braking
cycles per minute is not restricted.
If the ratio of the load inertia moment to the motor shaft inertia moment exceeds the stated
value, then please contact your sales representative.
If the servo motor is equipped with an electromagnetic brake, please take the relevant
figures from tab. 10-2.
Servo motor
HC-SFS Series (400V type)
524
1024
1524
2024
3524
5024
7024
Applicable servo amplifier
MR-J2S-
60B4
100B4
200B4
200B4
350B4
500B4
700B4
Rated output [kW]
0.5
1.0
1.5
2.0
3.5
5.0
7
Rated torque [Nm]
2.39
4.78
7.16
9.55
16.7
23.9
33.4
Rated speed [r/min]
2000
Maximum speed [r/min]
3000
2500
2000
Instantaneous permissible speed
[r/min]
3450
2850
2300
Maximum torque [Nm]
7.16
14.4
21.6
28.5
50.1
71.6
100
Inertia moment J
[kg
×
cm
2
]
6.6
13.7
20.0
42.5
82
101
160
Recommended ratio of load inertia
moment to servo motor shaft
inertia moment
≤
15
Regenerative
brake duty
cycle
[per minute]
Servo amplifier's built-
in regenerative brake
resistor
125
200
136
64
43
39
32
MR-PWR T150-270
415
—
—
—
—
—
—
MR-PWR T400-120
—
600
—
—
—
MR-PWR T600-80
—
—
680
320
—
—
—
MR-PWR T600-47
—
—
—
—
167
150
—
MR-PWR T600-26
—
—
—
—
—
—
95
Power supply capacity [kVA]
1.0
1.7
2.5
3.5
5.5
7.5
10
Rated current [A]
1.5
2.8
4.4
5.411
8.6
14
17
Maximum current [A]
4.5
8.4
13.2
16.2
25.8
42
51
Speed/position detector
Encoder (resolution: 131072 pulse/rev)
Protection type
IP65
Cooling
Self-cooled
Environmental conditions
Refer section 2.1
Weight [kg]
5.0
7.0
9.0
12.0
19.0
23
32
Tab. 10-6:
Standarddaten des Servomotors
Summary of Contents for MELSERVO MRJ2S-B
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...VIII ...
Page 18: ...Contents XII ...
Page 48: ...Introduction System configuration 1 30 ...
Page 58: ...Installation General environmental conditions 2 10 ...
Page 86: ...Connection Station number setting 3 28 ...
Page 122: ...Operation Gain 4 36 ...
Page 134: ...Absolute position detection system General description 6 6 ...
Page 146: ...Accessories Special accessories 7 12 ...
Page 148: ...Maintenance and Inspection Life 8 2 ...
Page 174: ...Specifications Standard specifications 10 16 ...
Page 176: ...EMC Directives Requirements 11 2 ...
Page 198: ...Index iv ...
Page 199: ......