10 BLOCK LINK EXAMPLES
10.8 Ratio Conversion
■
Multi function counter block detail window
• Counter_0 (32bit_Unsigned)
*1 Conversion ratio = Addition value
÷
(Upper limit value
÷
2)
The items other than the above need not to be set.
Block
Variable name
Setting value
Description
Input 0
Input_Signal_Event
Detector Select
User Setting
(A: Rise ON, A: Fall ON)
Set "A: Rise" and "A: Fall" to "ON" and the others to
"OFF".
Detector Select
This parameter is not used in this link example.
Counter_Timer_0
Count Enable
ON
Set this parameter to "ON".
Count Mode
Ring
Set this parameter to "Ring".
Upper Limit
20
Set this parameter according to the control.
Lower Limit
0
Set "0".
Clock
25ns
Set this parameter to "25ns". (to prevent input pulses
from missing)
Add Mode
ON
Set this parameter to "ON".
Add Value
3
Set this parameter according to the control.
Cam_Switch
Number of Step
1
Set "1" to enable the step No. 0.
Lower Limit Output State
Low
Set this parameter to "Low".
Step No.0
10
Set the value of "Upper limit value of the counter
timer block
÷
2".
Cam Output