9 CREATING A HARDWARE LOGIC
9.1 Main Blocks in the Hardware Logic Outline Window
121
9
Receive data monitor
Out of the data frame received from the SSI encoder, the information for the number of bits specified with "Data Frame
Length" is stored in the following buffer memory areas. (The parity bit is not included.)
Some SSI encoders output not only position data (multi turn data, single turn data) but also status data in the data frame. The
status of encoder can be checked by reading out values of above buffer memory areas with a program.
In addition, when a count value is not refreshed properly, its cause (whether it is a receive data error or a parameter setting
error) can be identified by checking multi turn data and single turn data contained in the receive data monitor.
Ex.
The example shows the receive data monitor of when the SSI encoder with the data frame of the following configuration is
used.
• Data frame length: 28 bits
• Multi turn data: 14 bits
• Single turn data: 13 bits
• Status: 1 bit
• Parity bit: 1 bit
Signal error detection
An error of the external wiring to the SSI encoder can be detected.
When "Signal Error Detection" is set to "Enable", a signal error detection processing is performed. If an error occurs on the
external wiring to the SSI encoder, the SSI encoder block
DATA signal wire reverse error (error code: 109
H) or the SSI
encoder block
DATA signal error (error code: 10A
H) is output.
In addition, in the cycle where data is received from the SSI encoder with an error detected, the count value of the multi
function counter block linked to the SSI encoder block is not refreshed.
Buffer memory address
SSI encoder block
Un\G110, Un\G111
SSI_Encoder_0
Un\G114, Un\G115
SSI_Encoder_1
b31
b28 b27
b0
Receive frame from SSI encoder
Data frame length: 28 bits
Multi turn
14 bits
Single turn
13 bits
Status
1 bit
Status
1 bit
Multi turn
14 bits
0 (fixed)
Single turn
13 bits
Parity
1 bit
SSI receive data monitor 0
(Un/G110, Un/G111)
This is not reflected in
SSI receive data monitor.
Summary of Contents for MELSEC-L Series LD40PD01
Page 2: ......
Page 9: ...7 MEMO ...
Page 24: ...22 2 PART NAMES MEMO ...
Page 35: ...4 PROCEDURES BEFORE OPERATION 33 4 MEMO ...
Page 263: ......