222
13 PROGRAMMING
13.3 When the Module Is Connected to a Head Module
4.
Display the setting window for the intelligent function module detailed setting of the flexible high-speed I/O control
module (LD40PD01) and set the values as follows.
[Project window]
[Parameter]
[PLC Parameter]
[I/O Assignment]
button
5.
Display the setting window for the switch setting of the flexible high-speed I/O control module (LD40PD01) and set the
value as follows.
[Project window]
[Intelligent Function Module]
Module model name
[Switch Setting]
When the own station is disconnected, the operations of the flexible high-speed I/O control module differ depending on the
setting of "Hardware logic control valid/invalid during disconnecting" in the switch setting or that of "Error Time Output Mode"
in the intelligent function module detailed setting. For details, refer to the following.
Page 229 Operations of the flexible high-speed I/O control module when the head module is connected
6.
Display the setting window for the auto refresh setting of the flexible high-speed I/O control module (LD40PD01) and set
the values as follows.
[Project window]
[Intelligent Function Module]
Module model name
[Auto Refresh]
7.
Write the set parameters to the head module. Then reset the head module or power off and on the programmable
controller.
[Online]
[Write to PLC]
or
Power OFF ON