172
10 BLOCK LINK EXAMPLES
10
BLOCK LINK EXAMPLES
Various controls can be performed with the combinations of various blocks. This chapter shows link examples to perform the
following controls.
Control name
Description
Reference
Coincidence detection
Turns on the output of the multi function counter block at coincidence detection.
One-shot timer
Turns on the output of the multi function counter block for the specified time period.
After the specified time period, the output is turned off until the next event detection.
Event generation
Outputs an external input signal as an event signal. The output signal can be linked
as an event signal of other multi function counter blocks.
Cam switch
Turns on or off the output when a count value within the upper and lower limit value
range becomes equal to or larger than the setting value of the corresponding steps.
PWM output
Outputs a PWM wave with the specified cycle and duty ratio.
Fixed cycle output
Outputs one pulse at every specified cycle.
Latch counter
Latches (holds) a count value.
Ratio conversion
Outputs an input signal multiplied with the set ratio (x/y).
Pulse measurement
Measures the ON width and OFF width of an input pulse.