10 BLOCK LINK EXAMPLES
10.7 Latch Counter
193
10
10.7
Latch Counter
The current value is latched (held) as a latch count value.
The following describes a link and parameter example of a latch counter. With the example setting, when a rise of the latch
input signal is detected, the current value is latched. Note that this link example is for when a 32-bit unsigned multi function
counter block is used.
Link and parameter
The following shows a link example of the hardware logic outline window and a link example and parameter setting example
of the multi function counter block detail window.
■
Hardware logic outline window
Phase A input pulse
Phase B input pulse
Latch signal