18. TROUBLESHOOTING
18.1 GOT Restoration Sheet
18 - 3
17
MA
INTENA
N
C
E
AND
IN
SPE
CTIO
N
18
T
ROUBL
ESHOOT
ING
APP
ENDICES
(2) Status of the GOT when it freezes (screen operation stopped)
(3) Status of the PLC CPU
Phenomenon
Cause/status
Action
(e) Buzzer sound
Does not sound.
Buzzer sound:
( )
Example: The rhythm as three beeps, one beep,
and then two beeps is repeated.
Proceed to (2) Status of the GOT when it
freezes.
Continues to beep randomly.
Continues to beep in a
particular pattern.
Beeps continuously.
The read device of the system information may
have turned ON when the device was set, turning
ON the Buzzer output signal.
Check the setting of the read device.
When the Buzzer output signal has no error,
proceed to (2) Status of the GOT when it
freezes.
Phenomenon
Cause/status
Action
(a) Switching to the utility
Enabled
Error code (system alarm):
( )
Example: 460 Communication unit error
When the system alarm display function can
be used, take the action for the error code
(system alarm) displayed.
If the action cannot be taken, proceed to (2)-
(b).
Disabled
The system alarm display function cannot be
used.
Proceed to (2)-(c).
(b) Executing of I/O check from the GOT utility
Communication error
Display details:
( )
Example: A message indicating the cause may be
a connection error was displayed.
Proceed to (2)-(c).
No error
The hardware such as a communication interface
has no error.
Proceed to (3) Status of the PLC CPU.
(c) Objects not displayed on the monitor screen
Found
Details:
( )
Example: The numerical display object is not
displayed.
Proceed to (3) Status of the PLC CPU.
Not found
Phenomenon
Cause/status
Action
(a) PLC failure
Occurs always.
An error such as CONTROL-BUS. ERROR or SP.
UNIT LAY. ERROR may have occurred.
Error code (system alarm):
( )
Example: 1204 CPU H/W fault
Proceed to the following.
Occurs sometimes.
The PLC CPU may be influenced by noise or the
hardware may be faulty.
Occurrence frequency:
( )
Example: Once a month
Error code (system alarm):
( )
Example: 1204 CPU H/W fault
Proceed to (4) GOT restoration procedure.
Operates normally.
-
Summary of Contents for Got 1000
Page 1: ......
Page 2: ......
Page 14: ...A 12 ...
Page 26: ...1 4 1 OVERVIEW 1 1 Features ...
Page 34: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Page 38: ...3 4 3 SPECIFICATIONS 3 3 Power Supply Specifications ...
Page 42: ...4 4 4 PARTS NAME 4 3 Rear Face ...
Page 54: ...6 6 6 INSTALLATION 6 5 Installation Procedure ...
Page 104: ...10 18 10 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 10 3 Ethernet Setting ...
Page 226: ...13 92 13 FILE DISPLAY AND COPY PROGRAM DATA CONTROL 13 2 Various Data Control ...
Page 250: ...15 2 15 CLEANING DISPLAY SECTION CLEAN ...
Page 264: ...16 14 16 INSTALLATION OF COREOS BOOTOS AND STANDARD MONITOR OS 16 5 CoreOS ...
Page 272: ...17 8 17 MAINTENANCE AND INSPECTION 17 5 Backlight Shutoff Detection ...
Page 298: ...App 6 APPENDICES Appendix 1 External Dimensions ...
Page 302: ...App 10 APPENDICES Appendix 3 Transportation Precautions ...
Page 306: ...REVISIONS 2 ...
Page 309: ......
Page 310: ......