Ensure that the monitor IP address setting is correct. Changing the network
settings may result in network disconnection. Contact your service personnel
if you have any problems on setting the IP address.
6.3
Connecting the Monitor to the CMS
You can connect the monitor to the BeneVision CMS. When connected to the CMS, the
system provides the following function.
■
The monitor can transmit parameter values, waveforms, alarm settings (if the
monitor is working in
Continuous Monitoring
mode), and events to the CMS.
From the CMS, you can check the patient’s data and alarms (if any).
■
When the monitor is working in
Continuous Monitoring
mode, patient
information, alarm settings, and alarm status can be synchronized between the
monitor and the CMS.
■
You can start or stop NIBP measurement from the CMS.
■
In case of network disconnection, the monitor can transmit the offline data to the
CMS when network is reconnected.
For more information on the CMS, see
the operator's manual of corresponding central
monitoring system.
To select a CMS, select the system status information area at the top right corner of the
main screen. Select the desired CMS from the popup CMS list.
NOTE
•
You can select CMS only when the Select CMS switch is on. For more
information, refer to
18.16.5 The Transfer Setup Tab
6.4
Connecting the eGateway
You can connect the monitor to the eGateway to implement interaction between the
monitor and external devices. When connected to the eGateway, the system provides
the following functions:
■
The monitor can transmit parameter values, waveforms, alarm settings (if the
monitor is working in
Continuous Monitoring
mode), and events to the
eGateway.
■
Clock can be synchronized between the monitor and the eGateway.
6.5
MLDAP
MLDAP refers to Mindray LDAP (Lightweight Directory Access Protocol). It is an
independent process which can be installed on eGateway or other application server
(Windows). MLDAP provides user identity and authentication.
Summary of Contents for VS 8A
Page 1: ...VS 9 VS 9A VS 9C VS 8 VS 8A VS 8C Vital Signs Monitor Operator s Manual ...
Page 2: ......
Page 8: ...2 6 This page intentionally left blank ...
Page 26: ...1 6 This page intentionally left blank ...
Page 58: ...3 24 This page intentionally left blank ...
Page 66: ...5 4 This page intentionally left blank ...
Page 70: ...6 4 This page intentionally left blank ...
Page 98: ...8 16 This page intentionally left blank ...
Page 142: ...13 4 This page intentionally left blank ...
Page 162: ...15 16 This page intentionally left blank ...
Page 166: ...16 4 This page intentionally left blank ...
Page 202: ...19 8 This page intentionally left blank ...
Page 224: ...22 10 This page intentionally left blank ...
Page 250: ...B 8 This page intentionally left blank ...
Page 260: ...C 10 This page intentionally left blank ...
Page 271: ...D 11 This page intentionally left blank ...
Page 272: ...D 12 ...
Page 275: ...F 1 F Declaration of Conformity ...
Page 276: ...F 2 This page intentionally left blank ...
Page 277: ......
Page 278: ...P N 046 020097 00 4 0 ...