5-56 Image Optimization
Acquisition Time
The time required for a complete acquisition.
Range: 7.5~17.5 secs.
Angle
The range from acquisition beginning to acquisition end.
Range: 10~85°.
5.10.6.3 Color STIC 3D
The system also supports the color STIC 3D flow image function. For details, see “5.10.10
Color 3D.”
5.10.7 3D Layout
The function compiles the 3 MPRs together according to their relative positions, to provide a much
clearer interior anatomical structure.
This function is provided by the [Niche] option, and does not support Smart 3D image data.
Niche
1. Touch the [3D Layout] tab in the [Tools] tab on the touch screen, then the [Niche] button is
highlighted.
2. Touch [A]/[B]/[C]/[Niche] on the touch screen to select the reference plane as Plane A, Plane B,
Plane C or Niche.
3. Set the view direction for niche display mode using the touch screen: from the front of the reference
image or from the back.
4. Roll the trackball to view sectional images as necessary. Rotate <M>, <PW>, <Color> to perform
axial rotation or rotate the <4D> knob to adjust the nearest VOI section (cut plane) position.
Click [Reset Ori.] to reset the rotation, the center point position, and the position of the MPR.
3Slice
1. Touch the [3D Layout] tab on the touch screen, then touch [3Slice].
2. Touch [A]/[B]/[C]/[3Slice] on the touch screen to select the reference plane.
3. Roll the trackball to view sectional images as necessary. Rotate <M>, <PW>, <Color> to perform
axial rotation or rotate the <4D> knob to adjust the nearest VOI section (cut plane) position.
Click [Reset Ori.] to reset the rotation, the center point position, and the position of the MPR.
5.10.8 iPage
+
iPage
+
is iPage+SCV function. iPage (Multi-Slice Imaging) is a “Visualization” mode for displaying
sectional images. The data is presented as slices through the data set, which are parallel to each other.
When SCV (Slice Contras View) function is turned on, the system expands the parallel section images
into a slice region with a specified thickness, and draws this region with 3D rendering effect to enhance
the image.
NOTE: iPage
+
imaging is an option, and it is not available in Smart 3D mode.
5.10.8.1 Operating Procedures
iPage operation
1. Acquire necessary 3D/4D data.
Single-frame VR:
Summary of Contents for DC-80A
Page 2: ......
Page 24: ......
Page 44: ......
Page 59: ...System Preparation 3 15...
Page 67: ...System Preparation 3 23...
Page 68: ......
Page 80: ......
Page 299: ...Probes and Biopsy 13 19...
Page 304: ...13 24 Probes and Biopsy NGB 035 NGB 039...
Page 324: ......
Page 334: ......
Page 340: ......
Page 348: ......
Page 352: ......
Page 363: ...Barcode Reader B 11...
Page 368: ......
Page 382: ......
Page 391: ...P N 046 014137 00 3 0...