- 2-29 -
Abnormal Pattern
If an abnormal pattern like the one shown on the right is printed,
clean the heads. There are two types of cleaning. Select one of
them according to the result of the test pattern.
Normal :
Select this if any line is disappears.
Hard
:
Select this if the abnormal pattern is
not recovered.
If the printing quality is not improved, clean the suction nozzle and the caps. Refer to
"Chapter3 Daily Care"
STEPS:
1.
Touch the [CLEANING].
2.
Touch the JOG [ ] or [ ] to select the print
heads to be cleaned.
3.
Touch the JOG [ ] or [ ] to display the
print heads to be cleaned.
Select [*] for the heads not to be cleaned.
4.
Touch the [ENTER].
5.
Touch the JOG [ ] or [ ] to select a type
of cleaning.
6.
Touch the [ENTER].
7.
Touch the [ENTER] to start the cleaning.
Cleaning is started.
8.
After the cleaning, the printer returns to
the LOCAL mode.
9.
Origin has been setting automatically.
Therefore repeat printing the test pattern, and
check the result.
CLEANING
COLOR
:KCMYcmW
<< LOCAL >>
** CLEANING**
******----------------
CLEANING
START
:ent
CLEANING
TYPE
:NORMAL
CLEANING
COLOR
:K**Y****
CLEANING
COLOR
:KCMYcmW
CLEANING
TYPE
:HARD
Summary of Contents for UJF-605RII
Page 22: ... xx ...
Page 82: ... 2 40 ...
Page 104: ... 3 22 ...
Page 114: ... 4 10 ...
Page 148: ... 5 34 ...
Page 162: ... A 6 ...
Page 168: ...A 12 D201670 1 10 27122007 ...
Page 169: ......
Page 170: ...Printed in Japan MIMAKI ENGINEERING Co Ltd 2007 EM FW 1 10 ...