STEPS:
1.
Touch the [FUNCTION] in the LOCAL
mode.
2.
Touch the JOG [ ] or [ ] to select the
[MAINTENANCE].
3.
Touch the [ENTER].
4.
Touch the JOG [ ] or [ ] to select the [UV
LAMP].
5.
Touch the [ENTER].
6.
Select the [LEVEL CHECK] and then,
touch the [ENTER].
7.
Touch the [ENTER] to move the carriage to
the capping station.
The carriage is moved.
8.
Open the left maintenance cover.
9.
Remove the flushing tray and then, set the
UV illuminometer.
MAINTENANCE
UV LAMP
< ent>
FUNCTION
MAINTENANCE
< ENT >
FUNCTION
DATA CLEAR
< ENT >
UV LAMP
LEVEL CHECK
< ent>
PLEASE OPEN
THE LEFT COVER
∗∗
MOVING
∗∗
PLEASE WAIT
UV LEVEL CHECK
HEAD MOVE
:ent
MAINTENANCE
LIST
< ent>