![MIMAKI UJF-605RII Operation Manual Download Page 155](http://html.mh-extra.com/html/mimaki/ujf-605rii/ujf-605rii_operation-manual_1800344155.webp)
- 6-7 -
Error message
Cause
Corrective measures
ERROR 34
DATA REMAIN
ERROR 30
OPERATION
ERROR 24
I / F INITIAL
ERROR 23
HOST I / F
ERROR 20
I / F BOARD
Settings for functions is tried to be
changed though received data that
has not been printed yet remains.
A wrong operation is performed on
the touch panel.
An initial operation failure of the I/F
board and the control circuit board.
A timeout error occurs during
communication between the host
computer and the interface board.
An error occurs on the interface of
the I/F board and the control circuit
board.
Print all of received data or perform
the data clear function. Then,
change the settings.
Perform a proper operation.
Turn off the power and turn it on
after a while. If the same error
message appears again on the
LCD, contact your local distributor to
call for service.
Check that the cable is securely
connected Also, check an error
does not occur in the computer.
Turn off the power and turn it on
after a while. If the same error
message appears again on the
LCD, contact your local distributor to
call for service.
ERROR 40
MOTOR X
The X motor has been overload.
ERROR 53
STEP MOTOR ORIGIN
ERROR 51
Y ORIGIN
ERROR 50
X ORIGIN
ERROR 44
SCAN RANGE
ERROR 43
Y CURRENT
ERROR 42
X CURRENT
ERROR 41
MOTOR Y
The step motor origin can not be
detected.
The Y origin could not be detected.
The X origin could
not be detected.
Out of scanning is occurred.
The overcurrent error on the Y
motor has been detected.
The overcurrent error on the X
motor has been detected.
The Y motor has been overload.
Turn off the power and turn it on
after a while. If the same error
message appears again on the
LCD, contact your local distributor to
call for service.
Summary of Contents for UJF-605RII
Page 22: ... xx ...
Page 82: ... 2 40 ...
Page 104: ... 3 22 ...
Page 114: ... 4 10 ...
Page 148: ... 5 34 ...
Page 162: ... A 6 ...
Page 168: ...A 12 D201670 1 10 27122007 ...
Page 169: ......
Page 170: ...Printed in Japan MIMAKI ENGINEERING Co Ltd 2007 EM FW 1 10 ...