© 2013 MIMAKI ENGINEERING CO.,LTD.
7.1.4
P.3
7.1.4 List of SYSTEM HALT
R.1.1
22
SYSTEM HALT (*)
406 : Y ORGIN
Y Origin Sensor error
1. Execute and confirm [#TEST SENSOR TEST] ->
[Y-ORG]. (Confirm that the ON/OFF display is switched by
moving the carriage left and right.)
2. Check in manual if the carriage moves left and right
smoothly.
3. Check the connector connection of Y-origin Sensor and then
disconnect and connect the cabel.
4. Replace the Y Origin Sensor with a new one.
5. Check if there is no trouble on theY Motor Cable.
(disconnecting, burnout, or the like)
6. Replace the Y-axis motor with a new one.
7. Replace the HDC PCB with a new one.
8. Replace the MAIN PCB with a new one.
23
SYSTEM HALT (*)
509 : HDC POSCNT
HDC position counter error
1. [Execute and confirm [#TEST SENSOR TEST]->
[Y-ORG].(Confirm that the ON/OFF display is
switched by moving the carriage left and right.)
2. Execute [#TEST CHECK ENCODER].
3. Check the assembly of Y-scale, and confirm that there is
neither dirt nor scratch.
4. Check in manual if the Head assy. (carriage) moves left and
right smoothly.
5. Check the connector connection of Y-origin Sensor and
Linear Encoder.
6. Replace the Y-origin Sensor or Linear Encoder with a new
one.
7. Check the assembly and connector connection of Y-axis
Motor.
8. Replace the Y-axis Motor with a new one.
9. Replace the HDC PCB with a new one.
10. Replace the MAIN PCB with a new one.
24
SYSTEM HALT (*)
801 : (C)OPCODE
System error
(CPU exception: OP code error)
11. Check the peripheral temperature of MAIN PCB, and then
check if the error is caused by the thermo runaway of CPU.
12. Make sure that there is no device generating strong radio
wave in the vicinity.
13. Replace the MAIN PCB with a new one.
14. Replace the DC Power Supply(5V) with a new one.
25
SYSTEM HALT (*)
802 : (C)SLOT
System error
(CPU exception: Slot instruction error)
26
SYSTEM HALT (*)
803 : (C)CPU ADDR
System error
(CPU exception: CPU address error)
27
SYSTEM HALT (*)
804 : (C)DMA ADDR
System error
(CPU exception: DMA address error)
28
SYSTEM HALT (*)
805 : (C)ZERO DIV
System error
(CPU exception: Division by 0)
List of SYSTEM HALT ?3/4?
No.
LCD
Cause
Corrective Measures
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of SYSTEM HALT
Model SWJ-320S Issued 2012.07.19 Revised 2012.12.14 F/W ver 1.0 Remark
1.1
Summary of Contents for SWJ-320 S2
Page 209: ......
Page 210: ...D500764 12 28082013 MIMAKI ENGINEERING CO LTD 2013 WK FW 2 20 ...