6.9.2
P.1
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Drying unit relations > Drying Fan assy.
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver
Remark
1.0
6.9.2 Drying Fan assy.
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Turn off the main power of drying fan unit, and then unplug the
power plug from the drying fan unit.
3. Unscrew the screws of both sides of the drying fan unit, and
remove the drying fan unit from the main body.
4. Remove the cable duct lid of the back of drying unit.
5. Disconnect the connector of the warm breeze assy. from the
relay connector.
6. Disconnect the FG wire connected to the drying fan assy.
7. Remove the screw, and remove the drying fan assy..
8. Reverse the disassembly procedure for reassembly.
Drying fan assy. (x8)
Unplug the power plug
Screw(x2)
Drying fan unit
Screw(x2)
When the drying fan unit is removed, be sure to
work with more than two persons, paying atten-
tion not to drop it nor damage the surroundings.
Drying fan assy.
Connector
FG wire mounting screw
Screw(x4)
Drying fan assy.