© 2013 MIMAKI ENGINEERING CO.,LTD.
6.2.2
P.3
6.2.2 Head Unit
R.1.0
For head cable connecting
Head relay PCB side
HDC PCB side
HDC1 PCB
HDC2 PCB
Head cable
Insulation lock (x2): Secure
the relay PCB from the gap of
the left and right lock lever.
When the head cables are
connected to the head relay
PCB, firmly connect them
so that the left and right
lock lever become in the
locked condition.
Additionally, the head
cables are easily unplugged and it may cause damage to the
HDC PCB and the head. Therefore, secure the head cables
and the connection connector part of head relay PCB,
using the insulation locks. Firmly secure them not to cause
any connector unplugging or lock lever unlocking.
Unlocked condition
Locked condition
MAINTENANCE MANUAL > Disassembly and Reassembly > Ink-related Parts > Head Unit
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver
Remark
1.0
Summary of Contents for SWJ-320 S2