6.7.2 Take-up Slack Sensor assy.
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the following covers.
• Feeding/take-up left side cover
3. Remove the terminal block cover, and disconnect the sensor
cables (A4, A21) from the terminal block, loosening the screw.
4. Disconnect the sensor cable (A25) from the relay socket termi-
nal, loosening the screw.
キ
5. Loosen the screws, and remove the
take-up slack sensor cover
.
6. Remove the
sensor BKT
from the main body.
7. Remove the
take-up slack sensor assy.
from the sensor BKT.
8. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Additionally, if electric charges are still remaining, it may cause damage to electronic parts or the like.
Take-up Slack Sensor assy.
Terminal block
Relay socket
Take-up Slack
Sensor assy.
Loosen the screw.
Loosen the screw.
Take-up Slack Sensor assy.
Loosen the screw.
Sensor
BKT
Take-up Slack
Sensor assy.
Screw(x2)
If the sensor mounting angle is shifted by replac-
ing or removing the sensor, perform the angle
adjustment.
(See
4.3.7 Slack sensor Optical axis adjustment
)