ERROR 62a
INK EXPIRATION(2M)
Ink expiration date has passed
(more than two months ago).
1. Replace it with a new ink bottle and perform charging.
2. If the error occurs even if the ink expiration date has not
passed, reset the date from [#ADJUST] -> [TIME SET] and
restart.
48
ERROR 618
TANKlevelH :1234
Sub-tank sensor abnormality
(Though a certain amount was consumed,
there is no change in the sub-tank sensor.)
49
ERROR 61b
SUPPLY INK:1234
Ink filling into the sub-tank has failed.
1. With [#TEST SENSOR], check the detection status of the
target liquid level detection sensor. (Also, visually check
the float position in the sub-tank.)
2. From [#TEST AGEING] -> [PUMP MOTOR], discharge
ink in the sub-tank to the bottom.
From [#TEST AGEING] -> [INK SUPPLY], check
that sending ink is performed.
*If sending ink cannot be performed: The supply
pump, the cartridge valve and the UISS valve shall
be replaced.
50
ERROR 707
!HD HEATER BRK
Is the heater of the head disconnected?
(The temperature does not rise after heat-
ing for over a certain period of time.)
1. Check the room temperature is not too low.
2. Replace the Print Head with a new one
.
3. Replace the HDC PCB with a new one.
51
ERROR 901
INVALID OPERATION
Operation error.
(You performed an invalid operation.)
52
ERROR 902
DATA REMAIN
Drawing data is remaining.
(Carry out the followings if the error still occurs when
data is cleared.)
1. Check errors in the parameter.
2. Remove USB cable from the printer and execute data clear.
-> If solved, it is a problem on USB cable or PC.
3. Replace the USB Cable with a new one.
4. Replace the MAIN PCB with a new one.
53
ERROR 909
PARAMETER VERSION
The version of DOWNLOAD parameter
differs from that of F/W.
1. Check whether the F/W version at uploading parameters
matches the F/W version of the machine.
2. If the F/W version of the machine is older, perform
parameter DOWNLOAD again after upgrading the version.
54
ERROR 04
PARAM ROM
Access Error of the PARAMETER ROM
1.The state that cannot access “FROM” on
the MAIN PCB.
2.The state that cannot access “EEPROM”
on the Central-IO PCB.
1. Replace the FFC and cable located between the HDC PCB
and the MAIN PCB.
2. Replace the FFC and cable located between the HDC PCB
and the MAIN PCB.
3. Replace the Central-IO PCB with a new one.
4. Replace the MAIN PCB with a new one.
List of Error Messages ?5/5?
No.
LCD
Cause
List of Countermeasures
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model SWJ-320S Issued 2012.07.19 Revised 2012.12.14 F/W ver 1.0 Remark
1.1
Summary of Contents for SWJ-320 S2
Page 209: ......
Page 210: ...D500764 12 28082013 MIMAKI ENGINEERING CO LTD 2013 WK FW 2 20 ...