© 2013 MIMAKI ENGINEERING CO.,LTD.
6.7.4
P.1
R.1.1
MAINTENANCE MANUAL > Disassembly and Reassembly > Repeated winding relations > Take-up Motor assy.
Model
SWJ-320S
Issued 2012.07.19 Revised 2012.08.17 F/W ver
Remark
1.1
6.7.4 Take-up Motor assy.
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the following covers.
• Feeding/take-up left side cover
3. Remove the terminal block cover, and disconnect the take-up
motor cables (A4, A23, A24) from the terminal block, loosen-
ing the screw.
4. Remove the screw, and remove the
take-up motor BKT
.
5. Loosen the set screw, and remove the
take-up motor gear
.
6. Remove the screw, and remove the
take-up motor assy.
.
7. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Additionally, if electric charges are still remaining, it may cause damage to electronic parts or the like.
Take-up Motor assy.
Feeding/take-up left side cover
Terminal block
Loosen the screw.
Take-up Motor
assy.
screw(x5)
Take-up motor BKT
Set screw
Take-up motor gear
Take-up motor gear
Summary of Contents for SWJ-320 S2
Page 209: ......
Page 210: ...D500764 12 28082013 MIMAKI ENGINEERING CO LTD 2013 WK FW 2 20 ...