© 2013 MIMAKI ENGINEERING CO.,LTD.
6.3.2
P.1
R.1.1
6.3.2 Y-axis Motor
Work procedures
1. Turn off the main power supply.
2. Loosen the screws to make the belt tension free.
3. Remove the
YM top plate
together with the bearing.
4. Remove the
YM stud
.
5. Disconnect the connector.
6. Remove the Y-axis motor together with the YM-BKT.
7. Remove the
YM-BKT
from the Y-axis motor.
8. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode func-
tions mistakenly during the operation.
Proceed with the work after well confirmed the following processes in advance.
3.2.2 Replacement of the Y-axis Motor
Screw
YM top plate
YM stud (x2)
Screw
YM-BKT
Connector
YM-BKT
Y-axis motor