23
22
.............. 4587 95 02... ......... 4588 05 02... ...........4699 82 02
.............. 4588 15 02...
..000001-999999..
..000001-999999..
..000001-999999..
............... 230 .V ......................110 V ................. 220-240 V
................. 50 .Hz ..................... 50 Hz ................... 50-60 Hz
................. 16 .A ....................... 25 A ............................10 A
.................... I .............................. I .................................I
.............IP X4 .......................IP X4 .........................IP X4
............. 2400 .W .................. 1000 W ..................... 2300 W
............. 2400 .W
............. 1200 .W .................. 1000 W ..................... 1200 W
............... 270 .m
3
/h ................ 252 m
3
/h.....................270 m
3
/h
............... 270 .m
3
/h
............... 250 .hPa ................. 230 hPa .....................250 hPa
................. 67 .dB(A) ................ 67 dB(A) ....................67 dB(A)
................... 2 .dB(A) .................. 2 dB(A) ......................2 dB(A)
............. < 2,5 .m/s
2
.............. < 2,5 m/s
2
.................. < 2,5 m/s
2
................. 30 .l ......................... 30 l .............................30 l
................. 42 .l
............. 2400 .W .................. 1750 W ......................1100 W
.............. ø 36 .mm ................ ø 36 mm .................... ø 36 mm
.............. 14,5 .kg ................... 14,5 kg .......................14,5 kg
.............. 16,0 .kg
............ H05RR-F3G1,5 ..... H07BQ-F3G2,5 ..... H05RR-F3G1,5
The appliance is suitable for picking up dry, non
fl
ammable dust, non
fl
ammable liquids, sawdust and hazadous dusts with OEL
1
) values
> 0.1 mg/m³
Dust Class M (IEC 60335-2-69). The dusts which belong to this class
are: dusts with OEL values
1)
> 0.1 mg/m³ as well as saw dust.
The machine is tested in its entirety by vacuums for this dust class. The
maximum degree of permeability is 0.1% and the disposal must be low
dust.
For dust extractors, ensure adquate air change rate M, when the
exhaust air is returned to the room. Observe national regulations before
use.
Electrical connection
• It is recommended that the machine should be connected via a
residual current circuit breaker.
• Arrange the electrical parts (sockets, plugs and couplings) and lay
down the extension lead so that the protection class is maintained.
• Connectors and couplings of power supply cords and extension leads
must be watertight.
Extension lead
As an extension lead, only use the version speci
fi
ed by the manufacturer
or one of a higher quality.
When using an extension lead, check the minimum cross-sections of the
cable:
Cable length
Cross section
< 16 A
< 25 A
up to 20 m
1.5 mm
2
2.5 mm
2
20 to 50 m
2.5 mm
2
4.0 mm
2
Important warnings
WARNING!
To reduce the risk of
fi
re, electric shock, or
injury, please read and follow all safety
instructions and caution markings before
use. This machine is designed to be safe
when used for cleaning functions as
speci
fi
ed. Should damage occur to
electrical or mechanical parts, the
machine and / or accessory should be
repaired by a competent service center or
the manufacturer before use in order to
avoid further damage to the machine or
physical injury to the user.
Do not leave the machine when it is
plugged in. Unplug from the socket when
not in use and before maintenance.
Do not use with damaged cord or plug. To
unplug grasp the plug, not the cord. Do
not handle plug or machine with wet
hands. Turn o
ff
all controls before
unplugging.
Do not pull or carry by cord, use cord as a
handle, close a door on cord, or pull cord
around sharp edges or cor ners. Do not
run machine over cord. Keep cord away
from heated surfaces.
Keep hair, loose clothing,
fi
ngers and all
parts of the body away from ope nings and
moving parts. Do not put any objects into
openings or use with opening blocked.
Keep openings free of dust, lint, hair, and
anything else that could re du ce the
fl
ow of
air.
Do not use in outside areas at low
temperature.
Outdoor use of the appliance must be
limited to occasional use.
Do not use to pick up
fl
ammable or
combustible liquids such as gasoline, or
use in areas where they may be pre sent.
Do not pick up anything that is burning or
smoking, such as cigarettes, mat ches or
hot ashes.
Use extra care when cleaning on stairs.
Do not use unless
fi
lters are
fi
tted.
If the machine is not working properly or
has been dropped, da ma ged, left
out doors, or dropped into water, re turn it
to a service center or dealer.
If foam or liquid escapes from the
machine, switch o
ff
immediately.
The machine may not be used as a water
pump. The machine is intended for
vacuuming air and water mixtures.
TECHNICAL DATA
DUST EXTRACTION
Production code
AS-30
MAC
.....................................................................................................
AS-42
MAC
.....................................................................................................
Volts ....................................................................................................................
Mains frequency .................................................................................................
Fuse ...................................................................................................................
Safety class .......................................................................................................
Type of protection...............................................................................................
Total connected load
AS-30
MAC
.....................................................................................................
AS-42
MAC
.....................................................................................................
Power
IEC
..............................................................................................................
Rate of air
fl
ow
AS-30
MAC
.....................................................................................................
AS-42
MAC
.....................................................................................................
Vacuum ..............................................................................................................
Sound pressure level L
p
IEC 60335-2-69 ..........................................................
Uncertainty K= ...................................................................................................
Vibration emission value a
hv
IEC 60335-2-69 ....................................................
Tank volume
AS-30
MAC
.....................................................................................................
AS-42
MAC
.....................................................................................................
Maximum power o
ff
-take....................................................................................
Suction hose diameter .......................................................................................
Weight according EPTA-Procedure 01/2014
AS-30
MAC
.....................................................................................................
AS-42
MAC
.....................................................................................................
Power supply cord .............................................................................................
OPERATING ELEMENTS
1. Hose diameter setting
2. Appliance
socket
3. Latch
4. Inlet
fi
tting
5. Inlet
cap
6. Container
7. Castor
8. Hose
hook
9. Handle
10. Accessory positions
11. Speed control
12. Switch
WARNING! Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric
shock,
fi
re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Instructions for use
The appliance must:
• only be used by persons, who have been instructed in its correct
usage and explicitly commissioned with the task of operating it
• only be operated under supervision
• This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge.
• Children shall be supervised to make sure that they do not play with
the appliance.
• Do not use any unsafe work techniques.
• Never use the appliance without a
fi
lter.
• Switch o
ff
the appliance and disconnect the mains plug in the following
situations:
- Prior to cleaning and servicing
- Prior to replacing components
- Prior to changing over the appliance
- If foam develops or liquid emerges
Besides the operating instructions and the binding accident prevention
regulations valid in the country of use, observe recognised regulations
for safety and proper use.
Before starting work, the operating sta
ff
must be informed on and trained
within:
• use of the machine
• risks associated with the material to be picked up
• safe disposal of the picked up material
Purpose and intended use
This mobile dust extractor is designed, developed and rigorously tested
to function e
ffi
ciently and safely when properly maintained and used in
accordance with the following instructions.
This machine is intended for commercial use, for example in hotels,
schools, hospitals, factories, shops, o
ffi
ces and rental businesses.
This machine is also suitable for industrial use, such as e.g. plants,
construction sites and workshops.
Accidents due to misuse can only be prevented by those using the
machine.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
Any other use is considered as improper use. The manufacturer accepts
no liability for any damage resulting from such use. The risk for such use
is borne solely by the user. Proper use also includes proper operation,
servicing and repairs as speci
fi
ed by the manufacturer.
The air
fl
ow in Safety Vacuum systems has to be strictly controlled to
achieve a minimum
fl
ow rate of V
min
= 20 m/s in the suction hose.
The safety label on the machine warns:
This appliance contains dust hazardous to health. Emptying and
maintenance operations, including removal of the dust collecting means,
must only be carried out by authorised personnel wearing suitable
personal protection. Operate only after the full
fi
ltration system has been
fi
tted and checked.
For dust extractors, ensure adquate air change rate H, when the
exhaust air is returned to the room. Observe national regulations before
use.
For Dust Class M machines (with type designation -2M) following
applies:
ENGLISH
ENGLISH
Summary of Contents for AS-42 MAC
Page 93: ...184 185...