26
27
• Clean the water level limiting device regularly and check for signs of
damage.
Before emptying the container, unplug the machine. Disconnect the
hose from the inlet by pulling out the hose. Release the latch by pulling
them outwards so that the motor top is released. Lift up the motor top
from container. Always empty and clean the container and water level
limit system after picking-up liquids.
Empty by tilting the container backwards or sideways and pour the
liquids into a
fl
oor drain or similar.
Put back the motor top to the container. Secure the motor top with the
latches.
Heavy maneuvers can, by mistake, trigger the water level limiting
device. Should this happen; turn o
ff
the machine and wait for 3 seconds
to reset the device. Continue to operate the machine afterwards.
Wet
fi
lters and interior part of the liquid container shall be dried before
storage
Dry pick-up
CAUTION
!
Picking up environmentally hazardous materials.
Materials picked up can present a hazard to the environment.
• Dispose of the dirt in accordance with legal regulations.
Before use, operators shall be provided with information, instruction and
training for the use of the machine and the substances for which it is to
be used, including the safe method of removal and disposal of the
material collected.
Remove the electrical plug from the socket before emptying after dry
pick-up. Remove the suction hose from the machine and close the inlet
cap, to avoid harmful dust spreading. Release the latch by pulling them
outwards so that the motor top is released. Lift up the motor top from
container.
Main Filter: check the
fi
lter. To clean the
fi
lter you can either brush or
wash it. Wait until the
fi
lter is dry before re-starting dust pick-up.
Dustbag: check bag to ensure the
fi
ll factor. Replace dust bag if
necessary. Remove the old bag. The new bag is
fi
tted by passing the
carboard piece with the rubber membrane through the vacuum inlet.
Make sure that the rubber membrane is passing past the heightening at
the vacuum inlet.
Safety
fi
lter bag: check bag to ensure the
fi
ll factor. Replace dust bag if
necessary. Wear mask and protective clothing when removing the old
bag. Carefully remove the dust bag connection from the inlet
fi
tting.
Close the dust bag connection with the slide. Dispose of the dirt in
accordance with legal regulations.
After emptying: close motor top to the container and secure the motor
top with the latches. Never pick up dry material without
fi
lter
fi
tted in the
machine. The suction e
ffi
ciency of the machine depends on the size and
quality of the
fi
lter and dust bag. Therefore - use only Original
fi
lter and
dust bags.
Before being taken out of the hazardous zone, the device must be
decontaminated using a dust extraction method, wiped clean, or sealed.
All parts of the device must be regarded as contaminated if they are
removed from the hazardous zone and suitable measures must be taken
to prevent dust from spreading.
AFTER USING THE MACHINE
After use
Remove the plug from the socket when machine is not in use. Wind up
the cord starting from the machine. The power cord can be wound up
around the motor top or at the container or placed in the included hook,
or fastening means. Some variants have special storage places for
accessories.
Transport
• Before transporting the machine, close all the latches.
• Do not tilt the machine if there are liquids in the dirt tank.
• Do not use a crane hook to lift the machine.
• Do not lift the machine by the trolley handle
• Storage
CAUTION
!
Store the appliance in a dry place, protected from rain and frost. The
machine shall be stored indoors only.
Accessory and tool storage
For convenient transport and storage of accessories or tools, integrated
rails are found on side of machine which allows fastening with straps or
other means. A
fl
exible strap and hooks are included on back of machine
for attachment of suction hose or mains cable. For instruction see quick
reference guide.
An optional adapter plate with attachment system can be installed on top
of machine for fastening of 2-point or 4-point storage cases.
Remove the electrical plug from the socket before installing the adapter
plate.
CAUTION
!
Do not lift machine in adapter plate without having storage case safely
installed. Note the weight and balance of the appliance in case of
storage. Maximum weight of storage cases is 30 kg.
Recycling the machine
Make the old machine unusable.
1. Unplug the machine.
2. Cut the power cord.
3. Do not discard of electrical appliances with household waste.
As speci
fi
ed in European Directive 2012/19/EU on old
electrical and electronic appliances, used electrical goods
must be collected separately and recycled ecologically.
MAINTENANCE
Regular servicing and inspection
Regular servicing and inspection of your machine must be carried out by
suitably quali
fi
ed personnel in accordance with relevant legislation and
regulations. In particular, electrical tests for earth continuity, insulation
resistance, and condition of the
fl
exible cord should be checked
frequently.
In the event of any defect, the machine MUST be withdrawn from
service, completely checked and repaired by an authorized service
technician.
At least once a year, a Milwaukee technician or an instructed person
must perform a technical inspection including
fi
lters, air tightness and
control mechanisms.
For user servicing, the machine shall be dismantled, cleaned and
serviced, as far as is reasonably practicable, without causing risk to the
maintenance sta
ff
and others. Suitable precautions include
decontamination before dismantling, provision for local
fi
ltered exhaust
ventilation where the machine is dismantled, cleaning of the
maintenance area and suitable personal protection.
When carrying out service or repair operations, all contaminated items
which cannot be satisfactorily cleaned are to be disposed of; such items
shall be disposed of in impervious bags in accordance with any current
regulation for the disposal of such waste.
Maintenance
Remove the plug from the socket before performing maintenance.
Before using the machine make sure that the frequency and voltage
shown on the rating plate correspond with the mains voltage.
The machine is designed for continuous heavy work. Depending on the
number of running hours – the dust
fi
lter should be renewed. Keep the
machine clean with a dry cloth, and a small amount of spray polish.
During maintenance and cleaning, handle the machine in such a manner
that there is no danger for maintenance sta
ff
or other persons.
In the maintenance area
• Use
fi
ltered compulsory ventilation
• Wear protective clothing
• Clean the maintenance area so that no harmful substances get into
the surroundings.
CAUTION Clean the water level limiting device regularly and examine it
for signs of damage.
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described, please
contact one of our Milwaukee service agents (see our list of guarantee/
service addresses).
If needed, an exploded view of the tool can be ordered. Please state the
machine type printed as well as the six-digit No. on the label and order
the drawing at your local service agents or directly at: Techtronic
Industries GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.
EC DECLARATION OF CONFORMITY
We declare as the manufacturer under our sole responsibility that the
product described under “Technical Data” ful
fi
lls all the relevant
regulations and the directives 2011/65/EU (RoHS), 2014/30/EU,
2006/42/EC, and the following harmonized standards have been used:
EN 60335-1:2012+AC:2014+A11:2014
+A13:2017+A1:2019+A2:2019+A14:2019
EN 60335-2-69:2012
EN 55014-1:2017+A11:2020
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
EN IEC 63000:2018
Winnenden, 2020-12-01
Alexander Krug
Managing Director
Authorized to compile the technical
fi
le.
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
GB-DECLARATION OF CONFORMITY
We declare as the manufacturer under our sole responsibility that the
product described under “Technical Data” ful
fi
lls all the relevant
provisions of the following Regulations S.I. 2008/1597 (as amended),
S.I. 2016/1091 (as amended), S.I. 2012/3032 (as amended) and that
the following designated standards have been used:
BS EN 60335-1:2012+A13:2017
BS EN 60335-2-69:2012
BS EN 55014-1:2017+A11:2020
BS EN 55014-2:2015
BS EN 61000-3-2:2014
BS EN 61000-3-3:2013
BS EN IEC 63000:2018
Winnenden, 2020-12-01
Alexander Krug
Managing Director
Authorized to compile the technical
fi
le.
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
SYMBOLS
CAUTION! WARNING! DANGER!
Always disconnect the plug from the socket before
carrying out any work on the machine.
Please read the instructions carefully before starting
the machine.
Do not dispose of waste electrical and electronic
equipment as unsorted municipal waste.
Waste electrical and electronic equipment must be
collected separately.
Waste light sources have to be removed from
equipment. Check with your local authority or retailer
for recycling advice and collection point.
According to local regulations retailers may have an
obligation to take back waste electrical and electronic
equipment free of charge.
Your contribution to re-use and recycling of waste
electrical and electronic equipment helps to reduce
the demand of raw materials.
Waste electrical and electronic equipment contain
valuable, recyclable materials, which can adversely
impact the environment and the human health, if not
disposed of in an environmentally compatible manner.
Delete personal data from waste equipment, if any.
Dust Class M
(IEC 60335-2-69).
The dusts which belong to this
class are: dusts with OEL
values
1)
> 0.1 mg/m³ as well as
saw dust.
European Conformity Mark
British Confomity Mark
Regulatory Compliance Mark (RCM). Product meets
applicable regulatory requirements.
Ukraine Conformity Mark
EurAsian Conformity Mark
ENGLISH
ENGLISH
Summary of Contents for AS-42 MAC
Page 93: ...184 185...